Coroline Logo


Eaves Ventilation

Ideal for

  • Maintaining the mandatory 10-25mm
    continous air gap at the Eaves.
Corovent
Eaves Photo

Key Properties

Eaves Ventilation is a straight forward method of maintaining adequate airflow in the roof void. Corovent Over Fascia Vents.
Comprising an extensive range of products and accessories Corovent eliminates condensation and protects construction of
the eaves and roof-felt finishing.

Features

  • Designed to work with standard rafter spacing: 400, 450 & 600mm.
  • Maintenance Free.
  • Corrosion and rot resistant.
  • Over fascia vents are strong enough to resist collapsing under the
    weight of a roofers boot or rooftiles.
  • High quality rot resistant plastics allow strength and flexibility
    preventing alignment problems.

 


Roofline Vents
CF1 COMB FILTER
Comb Filter
Designed for use with profiled tiles it creates a barrier against birds and
large insects entering the cavity between the tiles and roof felt.
Installation- The base of the comb is marked with positions for nailing either
directly onto the fascia boards or on top of a Corovent over fascia vent if fitted.

CF1 Diagram

FT60
FASCIA TRAY
Fascia Tray
A professional way to terminate roofing felt at eaves allowing a clear puddle
free path, directing any moisture in the felt downwards into the gutter.
Installation- Position the fascia tray on top of the fascia board and nail in place.
Adjacent trays are designed to overlap to easily form a continuous run. The tray,
over fascia vent and comb fillers (if required) may be fixed in place simultaneously.
Ft60 Diagram
FV1/FV25
OVER FASCIA VENT
Over Fascia Vent

Corovent Over Fascia Vents provide discreet eaves ventilation which is undetectable once installed providing up to 25mm
continuous ventilation into the roof void.





FV10 & FV25 provide an integral 4mm grill preventing entry of large insects or rodents into the roof. Suitable for buildings with or without a soffit overhang, new or refurbishment projects, and in corbelled eaves situations.

OV10 LOW PROFILE OVER FASCI VENTS
Low Profile Over Fasci Vents OV10 Over Fascia Vent has a unique low profile design with an overall height of 16mm for minimum disruption to eaves detail with 10mm air gap.
OV10 Diagram

  Rafter Trays  
RT66/RT132 CONTINUOUS RAFTER TRAY
Rafter Trays

Available on a continuous roll and in tray format. The continuous rafter tray incorporates structural profiling which dramatically improves rigidity so a full 25mm air path is guaranteed down the line of the roof.

As insulation becomes ever thicker it is increasingly difficult to maintain a clear path to the eaves and locate the tray in the right place. Roof ventilation can either slide below the tray and block ventilation, or push against the upper end and causing blockage. Use of narrow trays which do not prevent this should be avoided.

Rafter Tray Diagram
RT RT STANDARD RAFTER TRAY
Standard RT Available to fit three rafter spacings. Two versions give either 10mm or 25mm continuous ventilation, depending on requirements of Building Regulations. They fit over the rafters above the wall plate and can be nailed or stapled to the rafters.
RF FLYSCREEN RAFTER TRAY
Flyscreen RF

Designed to act as a combined eaves ventilator, insect screen and rafter tray for open eaves situations. It features an integral insect grill and maintains over 10mm of continuous ventilation while ensuring a 25mm gap between the insulation and the underfelt. It is available to fit 3 rafter spacings. flyscreen rafter tray


RR REFURBISHMENT RAFTER
Refurbishment RR Designed to allow easy retro fitting, the tray is pushed into place from inside the void. Insulation is then installed. It provides 25mm of continuous ventilation.

Eaves Ventilation Kit
The COROVENT eaves ventilation kit provides a complete system to ventilate 6m of eaves, at any common rafter centres.

The kit is supplied in a sturdy box which contains:

1 x 6m roll Corovent continuous rafter tray: RT66 or 132
Eaves Kit

10 x Corovent eaves fascia trays : FT60
6 x Corovent over fascia vents : OV10 or FV25

HK1
Kit provides 10mm of continuous ventilation, with rafter tray 400mm wide.

HK2
Kit provides 25mm of continuous ventilation, with rafter tray 400mm wide.

HK21
Kit provides 10mm continuous ventilation, with rafter tray 800mm extra wide.

HK22
Kit provides 25mm of continuous ventilation, with rafter tray 800mm extra wide.
 
Soffit Vents
SD20 SOFFIT DISK VENT
SD20 Easy to retro fit to soffit during refurbishment, also used for ventilating new soffits, with a thickness of 4mm or more. Use with any roof pitch. One unit provides 2,000mm² ventilation, with a 4mm grid to keep out vermin and large insects. SD20 Diagram
SV10/SV25 CONTINOUS SOFFIT VENT
Continuous Soffit Vent Used with standard, horizontal soffit boards on new buildings. Soffit boards to be between 4mm and 10mm thick. Provides 10mm or 25mm of continuous ventilation. Sv Diagram
SA10 ANGLED SOFFIT VENT
Angled soffit vent

Highly versatile soffit vent can be used with vertical or angled fascia boards, and at the top or bottom of the soffit board. Ideal for new or existing buildings, fitting into soffits of any thickness. Provides 10mm of continuous ventilation.

SA Diagram

  continuous rafter tray standard rafter tray
-10mm air gap
standard rafter tray
-25mm air gap
flyscreen rafter tray refurb
 
Vent RT66 RT132 RT60 RT45 RT40 RT61 RT46 RT41 RF60 RF45 RF40 RR46
Rafter ALL ALL 600mm 450mm 400mm 600mm 450mm 400mm 600mm 450mm ALL ALL
Air Gap 25mm 25mm 10mm 10mm 10mm 25mm 25mm 25mm 10mm 10mm 10mm 10mm

 
 


Quicklink chooser

Frequently Asked Questions

DIY Roof Planner

Find A Stockist Near You